[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: Schematic import (was "why separate xgsch2pcb?")



Steven Michalske <smichalske@xxxxxxxxx> wrote:

> Out of curiosity, if you were to temporarily make a copy of the contents
> [...]

Changing out the symlink for a real directory full of files didn't help, but I believe I have found the problem:

Normally when you reference a stock footprint in a schematic, you do so by name, without any suffixes, e.g. you specify "RCY100" instead of "RCY100.fp".  This is how I reference my custom footprints as well, and it's enough to satisfy gsch2pcb.

I tried changing all references to my custom footprints in the schematic to include ".fp", and sure enough, it works.  The Import function finds them just fine this way.

This of course represents a significant change in behavior, so I'd have to suggest that the suffix be made optional in the Import function.

-- 
"There are some things in life worth obsessing over.  Most
things aren't, and when you learn that, life improves."
http://starbase.globalpc.net/~ezekowitz
Vanessa Ezekowitz <vanessaezekowitz@xxxxxxxxx>


_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user