[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: Out and In symbols in gschem & getting net names to come out in PCB
On Mon, May 2, 2011 at 9:16 AM, Rob Butts <r.butts2@xxxxxxxxx> wrote:
> Really? So now instead of having a nice clean schematic with net names
> like clk, _clk, reset and _reset I have to have clk:1, _clk:1...
> Is the way around that making the net attribute not visible and making
> the value attribute visible giving it the net name I want to show up on
> the schematic?
That would work, but then you have the burden of strictly keeping your
net attributes and name attributes synchronised. Failure to keep them
synchronised would result in nasty inconsistencies between your human
readable schematic and the machine output netlist.
Are there any gschem oldtimers around who can explain the rational for
the :1 requirement ?
If there's no good reason for it I'd be happy to write a patch that removes it.
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user