[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: terminators
Update...
I added serpentines to the short traces, and re-routed the long traces
to go under the sdram chip instead of around it, and got the
following... Only 381 mils difference between the shortest and
longest. http://www.delorie.com/electronics/sdram/
Net R_WE length 1.509 in
Net R_RAS length 1.519 in
Net R_CAS length 1.539 in
Net R_DQML length 1.554 in
Net R_A10 length 1.586 in
Net R_BA1 length 1.586 in
Net R_A0 length 1.587 in
Net R_DQ0 length 1.591 in
Net R_DQ3 length 1.592 in
Net R_A3 length 1.600 in
Net R_DQ2 length 1.614 in
Net R_DQ5 length 1.614 in
Net R_A1 length 1.615 in
Net R_BA0 length 1.615 in
Net R_A11 length 1.620 in
Net R_A2 length 1.620 in
Net R_DQ1 length 1.625 in
Net R_DQ4 length 1.627 in
Net R_CS length 1.657 in
Net R_CKE length 1.666 in
Net R_DQ7 length 1.675 in
Net R_DQ6 length 1.695 in
Net R_A9 length 1.729 in
Net R_A8 length 1.742 in
Net R_A7 length 1.762 in
Net R_A6 length 1.775 in
Net R_A5 length 1.795 in
Net R_DQ8 length 1.798 in
Net R_A4 length 1.826 in
Net R_DQ13 length 1.852 in
Net R_DQ11 length 1.855 in
Net R_DQ9 length 1.857 in
Net R_DQ12 length 1.867 in
Net R_DQ10 length 1.869 in
Net R_DQMH length 1.879 in
Net R_DQ14 length 1.883 in
Net R_DQ15 length 1.886 in
Net R_CLK length 1.890 in
And yes, I added a command to show the length of all nets.
Report(AllNetLengths). I also used a script to remove the logic
analyzer traces from the above report, and pull out the nets I wanted.
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx